Product ID5999881193336
-
Package size230x160x35 mm
-
Package weight0.27 kg
Main features:
- GSM communication
- 4 contact inputs
- 2 relay outputs
- Programmable through USB, GSM
Technical data:
- Transmission frequency:
GSM 900/1800 MHz or
GSM 850/1900 MHz - Supply voltage:
9-24 VDC - Current consumption:
Nominal: 120mA
Maximum: 500mA - Operating temperature:
-20°C - +70°C - Dimensions:
84 x 72 x 32mm - Weight: 200g
Characteristics of the GSM Pager:
- Electric contact signalization through GSM network:
- Reporting to monitoring station in Contact-ID format
- Voice call with recordable voice messages (8 x 8sec) to 4 phone numbers
- SMS sending to 4 phone numbers
- Independent alarm function
- Adjustable input sensitivity in tenth seconds, seconds and minutes
- Forwarding of incoming SMS messages (balance information of non-subscription type cards, etc.)
- Supply voltage supervision
- Firmware update through USB and GSM data call
- Arming / disarming through telephone, status query, remote control of outputs
- Control of relay outputs and status query in SMS
- Total remote diagnostics, monitoring of inputs and outputs, event list preview
- Programmable through USB and remote download
Technical specification
-
Transmission channelGSM
-
Frequency band900/1800, 850/1900 MHz
-
Operating temperature-20 C - +70 C
-
Supply voltage9-30 VAC/DC
-
Current consumption (maximum)500mA
-
Current consumption (nominal)100mA
-
CasingPlastic
-
Terminal connector designConnectable
-
Dimensions84x72x32 mm
-
Weight200 g
Inputs
-
Contact inputs4
-
Configurable inputs (NO/NC)Yes
-
Adjustable input sensitivityYes
Outputs
-
Relay outputs2
-
Output control through free GSM callYes
-
Output control with commands through GSM voice callYes
-
Output activation on GSM faultYes
Programming
-
Programming methodUSB / IP
-
Programming softwareYes
Users
-
User phone numbers for forwarding incoming SMS messages2
-
User phone numbers for reporting4
-
User phone numbers for output controlUnlimited
Remote monitoring
-
Monitoring station phone numbers2
-
Individual reporting to monitoring stationYes
Other functions
-
Configurable internal Contact ID event codesYes
-
Built-in internal clockYes
-
Security passwordYes
-
Event logs / Number of stored eventsYes / 1200
-
Caller identificationYes
-
Individual SMS sending to user phone numbers with built-in messageYes
-
Individual SMS sending to user phone numbers with predefinable messageYes
-
Periodic test reportYes
-
Alarm sending to user phone numbers with siren tone being usedYes
-
Alarm restrictionYes
-
Alarm control panel function (arming/disarming, entry and exit delay)Yes
-
Pre-recordable voice message sending to user phone numbersYes / 8
-
Selectable 24h zonesYes
-
Selectable confirmation request from user phone numbersYes
-
Why can I not make a call or send an SMS (Text) from the device?
If you have a SIM card that is prepaid, please check if you have the necessarily amount of money on it, to make a call or send an SMS (Text). Insert the SIM card into another mobile phone and try to make a call, send an SMS (Text), so you can check if there is a problem with the SIM card or the device. If the SIM card is working, please check the module power supply and power demand, and also the GSM antenna connection. Make sure that you adjusted the right number, and that you allowed it to make a call or send an SMS (Text) to this phone number.
-
When the call is made from the device, the phone does not display the caller’s number. Why?
You have to enable to send the caller ID of the inserted SIM card by the GSM provider. Put the SIM card into a mobile phone, and call the GSM provider customer service, in the menu, you will be able to enable that feature. (Even though the caller ID shows up when you make a call with a mobile phone, it will not show up when you use the device until you enable this feature through the GSM provider)
-
The device does not activate the relay output on an incoming call. Why?
The caller ID identification must be enabled on the inserted SIM by the GSM service provider. Without this, the device will be unable to identify the incoming call ID identification. Insert the SIM card (which is in the device) into a mobile phone; call the customer service of the GSM service and enable this service in the menu. Make sure you set the timing of the relay output (if the timing is 0, the relay will not activate).
-
Despite the fact that I received the call, the device makes a recall. Why?
Perhaps the machine is set that the call must be acknowledged. In this case, it will redial during the alarm time, until you acknowledge the alarm. You can do this by pushing the asterisk * button.
-
It is not possible to read or upload the setting to the device with the programming software. The connection does not get through, or sometimes the downloading stops.
Please power up the module first, after that connect it to the computer.
-
After installing the programmer software there is an error message saying that the DLL file is missing and it can not start.
Some operating systems create a missing DLL file after connecting to the module. Connect the module through a USB to the computer, and after this start the programming software again.
-
The module sends a long line of continuous letter / sequence SMS message to the SMS forwarding featured phone number. What is the reason for this?
This phenomenon happens when you do not receive a regular SMS (text) to the phone module, but some kind of a multimedia message (MMS photo) or some other encoded message (for example, encoded Cyrillic letters with accents or other capitalization). An industrial phone module is not able to handle this, that's why the mentioned letters/sequences are converted into Unicode form and are forwarded to your phone (depending on the size of the message 1 MMS can be received in 3 or 4 SMSs). Please note that in this case there is no problem with the device itself, but this phenomenon is caused by the above-described reason. If this occurs regularly, there is a good chance that it is an advertising / marketing message sent by the service provider, which can only be stopped by either asking the service-provider not to send such messages to this given phone number or by turning off the message forwarding function (in the settings: delete the SMS forwarding phone number), if this function is not absolutely necessary.