-
Product ID5999881193374
-
Package size170x120x35 mm
-
Package weight0.26 kg
Contact controlled communicator, which can be used as an optional reporting device for alarm control panels, for reporting states of switches or outputs by call and SMS, or for remote control through relay outputs. Free gate opening function, optional temperature measuring and control.
Main features:
- GSM communication
- 2 NO/NC contact inputs
- 2 NO relay outputs
- Possibility to connect temperature sensor (easyTEMP Compact)
- Programming by using software through USB or modem connection, or by SMS
- Supported operating system: Windows 10
Application area:
- Optional GSM communicator for alarm control panels
- Notification through voice call and SMS about the state of switches
- Remote relay control / control of electric gates by phone call for free
- Temperature monitoring and intervention through the outputs (optional)
Functions:
- GSM voice call to 4 user phone numbers on input activation with recordable message (2x6 sec.) or siren tone
- Reporting to monitoring station with Contact-ID protocol
- SMS sending with configurable message for each event
- Events:
- alarm on the 2 inputs
- temperature threshold alarms (optional)
- temperature sensor supervision (optional)
- low voltage alarm
- periodic test report - Control of relay outputs (monostable/bistable):
- by input events
- by phone call for free
- by temperature events (optional) - Adjustable input sensitivity
- Car alarm adaptation (monitoring of rhythmical regular impulses)
- Forwarding of incoming SMS messages (e.g. balance information, etc.)
Technical specification
-
Transmission channelGSM
-
Frequency band850/900/1800/1900 MHz
-
Operating temperature-20 °C – +70 °C
-
Supply voltage12-30V DC
-
Current consumption (maximum)200 mA @ 12 VDC
-
Current consumption (nominal)50 mA @ 12 VDC
-
CasingPCB + metal case
-
Terminal connector designMounted on the panel
-
Dimensions100x70x19 mm
-
Weight80 g
Inputs
-
Contact inputs2
-
Configurable inputs (NO/NC)Yes
-
Adjustable input sensitivityYes
Outputs
-
Relay outputs2
-
Output control through free GSM callYes
-
Output control by SMSYes
Notifications
-
GSM voice callYes
-
SMS sendingYes
-
DTMF-based reporting to monitoring stationYes
Supported protocols
-
SIA DC-05 (DTMF) protocolYes
Programming
-
Programming methodUSB / GSM data call (CSD) / SMS
-
Programming softwareYes
Users
-
User phone numbers for forwarding incoming SMS messages1
-
User phone numbers for reporting4
-
User phone numbers for output control4 / Unlimited
Remote monitoring
-
Monitoring station phone numbers1
-
Individual reporting to monitoring stationYes
Other functions
-
Configurable internal Contact ID event codesYes
-
Security passwordYes
-
Caller identificationYes
-
Possibility to connect temperature sensor (easyTEMP)Yes
-
Individual SMS sending to user phone numbers with predefinable messageYes
-
Temperature monitoring and intervention through the outputs (optional)Yes
-
Periodic test reportYes
-
Alarm sending to user phone numbers with siren tone being usedYes
-
Alarm restrictionYes
-
Pre-recordable voice message sending to user phone numbersYes / 2 x 6 sec
-
Selectable confirmation request from user phone numbersYes
-
The device does not activate the relay output on an incoming call. Why?
The caller ID identification must be enabled on the inserted SIM by the GSM service provider. Without this, the device will be unable to identify the incoming call ID identification. Insert the SIM card (which is in the device) into a mobile phone; call the customer service of the GSM service and enable this service in the menu. Make sure you set the timing of the relay output (if the timing is 0, the relay will not activate).
-
Despite the fact that I received the call, the device makes a recall. Why?
Perhaps the machine is set that the call must be acknowledged. In this case, it will redial during the alarm time, until you acknowledge the alarm. You can do this by pushing the asterisk * button.
-
The module sends a long line of continuous letter / sequence SMS message to the SMS forwarding featured phone number. What is the reason for this?
This phenomenon happens when you do not receive a regular SMS (text) to the phone module, but some kind of a multimedia message (MMS photo) or some other encoded message (for example, encoded Cyrillic letters with accents or other capitalization). An industrial phone module is not able to handle this, that's why the mentioned letters/sequences are converted into Unicode form and are forwarded to your phone (depending on the size of the message 1 MMS can be received in 3 or 4 SMSs). Please note that in this case there is no problem with the device itself, but this phenomenon is caused by the above-described reason. If this occurs regularly, there is a good chance that it is an advertising / marketing message sent by the service provider, which can only be stopped by either asking the service-provider not to send such messages to this given phone number or by turning off the message forwarding function (in the settings: delete the SMS forwarding phone number), if this function is not absolutely necessary.
Downloads
-
Compact GSM II EN-HU-DE Quick Start Guide
-
Compact GSM II v2-50-2209 Manual EN 04-11-2020
-
Compact GSM II Programming software v1-20 (Signed)
-
Compact GSM II volume adjusting application (Mixer.exe)
-
TELLtest_HID_logger_v2
-
Compact GSM II CE
-
Compact GSM II firmware v2-71
-
Compact GSM II Bootloader update
-
Firmware upgrade instructions
-
Bootloader update instructions
-
Release notes (EN)
Product updates
-
'14 Nov 06. -
'14 Dec 11. Compact GSM II - new firmware (v2.51.2242)
details -
'14 Oct 20. Compact GSM II - new firmware (v2.50.2209)
details -
'13 May 02. Compact GSM II - new firmware (v2.22-1822)
details -
'14 Apr 07. Compact GSM II - new firmware (v2.26.2093)
details -
'14 Mar 10. Compact GSM II - new firmware and programming software
details