• Product ID
    5999881193060
  • Package size
    230x160x35 mm
  • Package weight
    0.37 kg

Main features:

  • GPRS, backup GSM and PSTN communication
  • Management of 2 independent SIM cards
  • Installable behind phone exchange center
  • Management of different prefix numbers for PSTN and GSM calls
  • Forwards incoming SMS messages to 2 phone numbers
  • Stores the last 1000 events in the event list
  • 4 configurable NO/NC contact inputs onboard and optional 24 input expansion module
  • Reports the state of 4+24 inputs to monitoring station
  • Configurable Contact ID codes for each input and custom event
  • 4 configurable NO/NC relay outputs (monostable, bistable, state switching), controllable by events and/or by user
  • Backup battery management
  • GPRS channel supervision
  • Supply voltage supervision
  • On-board optical tamper protection
  • On-board micro speaker for line communication checking
  • Status LEDs

Technical specification

  • Transmission channel
    GPRS / GSM / PSTN
  • Frequency band
    900/1800, 850/1900 MHz
  • Operating temperature
    -20 C - +70 C
  • Supply voltage
    9-30 VDC
  • Current consumption (maximum)
    500mA @ 12VDC
  • Current consumption (nominal)
    120mA @ 12VDC
  • Casing
    No (PCB)
  • Terminal connector design
    Mounted to panel
  • Dimensions
    150x110x19 mm
  • Weight
    200 g

Inputs

  • Contact inputs
    4 / 28 (with expansion module)
  • Configurable inputs (NO/NC)
    Yes

Outputs

  • Relay outputs
    4
  • Output control by SMS
    Yes
  • Output activation on GSM fault
    Yes
  • Output activation on PSTN fault
    Yes

Supported protocols

  • TEX protocol
    Yes

Programming

  • Programming method
    USB / IP / GSM data call (CSD)
  • Programming software
    Yes

Users

  • User phone numbers for forwarding incoming SMS messages
    2

Remote monitoring

  • Monitoring station IP addresses
    6
  • Monitoring station phone numbers
    2
  • Individual reporting to monitoring station
    Yes

Other functions

  • Battery connection feature, intelligent charging
    Yes
  • Configurable internal Contact ID event codes
    Yes
  • Built-in internal clock
    Yes
  • Built-in micro speaker for communication testing
    Yes
  • Built-in tamper protection
    Yes
  • Security password
    Yes
  • Event logs / number of stored events
    Yes / 100
  • Dual SIM management
    Yes
  • Periodic test report
    Yes
  • PSTN line supervision
    Yes
  • Alarm restriction
    Yes
  • Phone line emulation
    Yes
  • Adaptation of alarm control panels to mobile network
    Yes
  1. The device does not activate the relay output on an incoming call. Why?

    The caller ID identification must be enabled on the inserted SIM by the GSM service provider. Without this, the device will be unable to identify the incoming call ID identification. Insert the SIM card (which is in the device) into a mobile phone; call the customer service of the GSM service and enable this service in the menu. Make sure you set the timing of the relay output (if the timing is 0, the relay will not activate).

  2. The device is not connecting to the GPRS net. Why?

    Check the APN settings, the power supply and power requirements of the module, as well as the GSM antenna connection and signal strength.

  3. After installing the programmer software there is an error message saying that the DLL file is missing and it can not start.

    Some operating systems create a missing DLL file after connecting to the module. Connect the module through a USB to the computer, and after this start the programming software again.

  4. The module sends a long line of continuous letter / sequence SMS message to the SMS forwarding featured phone number. What is the reason for this?

    This phenomenon happens when you do not receive a regular SMS (text) to the phone module, but some kind of a multimedia message (MMS photo) or some other encoded message (for example, encoded Cyrillic letters with accents or other capitalization). An industrial phone module is not able to handle this, that's why the mentioned letters/sequences are converted into Unicode form and are forwarded to your phone (depending on the size of the message 1 MMS can be received in 3 or 4 SMSs). Please note that in this case there is no problem with the device itself, but this phenomenon is caused by the above-described reason. If this occurs regularly, there is a good chance that it is an advertising / marketing message sent by the service provider, which can only be stopped by either asking the service-provider not to send such messages to this given phone number or by turning off the message forwarding function (in the settings: delete the SMS forwarding phone number), if this function is not absolutely necessary.

Message to the customer service

?

Downloads

Version:
  • GPRS ProCom v1-00-0096 Manual EN 12-08-2013
    2013.08.12 1.87 MB Download
  • GPRS-GSM ProCom Programming software v1-24 (without DotNET)
    2014.02.17 478.99 KB Download
  • GPRS-GSM ProCom Programming software v1-24 (DotNET included)
    2014.02.17 236.74 MB Download
  • Release notes
    2014.02.17 299 bytes Download
  • GPRS ProCom CE
    2011.08.15 619.31 KB Download
  • GPRS ProCom Leaflet EN
    2011.12.04 1.73 MB Download
  • GPRS ProCom firmware S900/S900R v1.00.0113
    2017.02.03 487.85 KB Download
  • Firmware upgrade instructions
    2014.09.03 1.91 KB Download
  • Release notes
    2017.06.02 1.58 KB Download
  • BootloaderX22 firmware upgrade instructions (EN)
    2012.08.17 1.86 KB Download
  • BootloaderX22 EN firmware upgrade utility
    2012.08.17 1.59 MB Download
no uploaded file