$ 108.00 + VAT (Br: $ 137.16 )
pcs
VAT value may change in regard to tax number of customer.

  • Product ID
    5999881193091
  • Package size
    170x120x35 mm
  • Package weight
    0.25 kg

Main features:

  • GPRS/IP and GSM communication
  • Direct IP communication with TELLMon receivers
  • Direct communication with SIA IP receivers through IP
  • Direct communication with DTMF receivers through backup GSM call
  • SIA IP and TELLMon protocol
  • 1 phone line output
  • Forwards incoming SMS messages
  • The programming software is available on the built-in USB storage
  • The IP addresses and other settings can be configured by SMS or PC

Characteristics:

  • Can be used with any alarm system which is able to report to monitoring station in Contact ID format using PSTN landline. Using the adapter, the alarm control panel’s signals are sent to the monitoring station’s IP receiver over the GPRS network, using SIA IP protocol based on ANSI/SIA DC-09-2007 standard.
  • There is no need for a central server, only an IP receiver with Internet connection is necessary. The adapter is able to communicate with receivers which support the SIA IP protocol.
  • Forwards the signals to 4 IP addresses, depending on the alarm control panel’s settings.
  • Contact ID communication over GSM voice call in case of IP error.
  • Possibility to send test report to more IP address and continuous monitoring of the connections, for which it evaluates and shows estimated data traffic.
  • Simple visual status display and full status information on PC platform.
  • By connecting the device to a PC, its internal memory acts as a USB drive, on which the programming software and manual are available.

Application area:

GPRS communicator for alarm control panels, which converts the Contact ID communication into SIA IP format and forwards the events towards the monitoring station’s receiver using IP channel over mobile GPRS network.

Technical specification

  • Transmission channel
    2G / GSM
  • Frequency band
    850/900/1800/1900 MHz @GSM/GPRS
  • Operating temperature
    -20 ºC - +70 ºC
  • Supply voltage
    12-30V DC
  • Current consumption (maximum)
    400 mA @ 12 VDC
  • Current consumption (nominal)
    80 mA @ 12 VDC
  • Casing
    PCB + metal case
  • Terminal connector design
    Mounted on the panel
  • Dimensions
    100x70x19 mm
  • Weight
    80 g

Notifications

  • GSM voice call
    Yes
  • SMS sending
    Yes
  • DTMF-based reporting to CMS
    Yes

Supported protocols

  • SIA IP DC-09 protocol
    Yes
  • SIA DC-05 (DTMF) protocol
    Yes
  • TELLMon protocol
    Yes

Programming

  • Programming method
    USB / SMS
  • Programming software
    Yes

Users

  • User phone numbers for forwarding incoming SMS messages
    1

Remote monitoring

  • Monitoring station IP addresses
    4

Other functions

  • Built-in internal clock
    Yes
  • Phone line emulation
    Yes
  • Adaptation of alarm control panels to mobile network
    Yes
  1. The device is not connecting to the GPRS net. Why?

    Check the APN settings, the power supply and power requirements of the module, as well as the GSM antenna connection and signal strength.

  2. It is not possible to read or upload the setting to the device with the programming software. The connection does not get through, or sometimes the downloading stops.

    Please power up the module first, after that connect it to the computer.

  3. The module sends a long line of continuous letter / sequence SMS message to the SMS forwarding featured phone number. What is the reason for this?

    This phenomenon happens when you do not receive a regular SMS (text) to the phone module, but some kind of a multimedia message (MMS photo) or some other encoded message (for example, encoded Cyrillic letters with accents or other capitalization). An industrial phone module is not able to handle this, that's why the mentioned letters/sequences are converted into Unicode form and are forwarded to your phone (depending on the size of the message 1 MMS can be received in 3 or 4 SMSs). Please note that in this case there is no problem with the device itself, but this phenomenon is caused by the above-described reason. If this occurs regularly, there is a good chance that it is an advertising / marketing message sent by the service provider, which can only be stopped by either asking the service-provider not to send such messages to this given phone number or by turning off the message forwarding function (in the settings: delete the SMS forwarding phone number), if this function is not absolutely necessary.

Message to the customer service

?

Downloads

Version:
  • ecoLINE SIA IP v5-02 Manual EN 15-09-2015
    2015.10.13 578.89 KB Download
  • ecoLINE SIA IP Programming software v1-10 (Signed)
    2014.07.01 501.57 KB Download
  • ecoLINE SIA IP volume adjusting application (Signed)
    2012.06.21 1.14 MB Download
  • ecoLINE SIA IP CE
    2012.11.15 606.92 KB Download
  • ecoLINE SIA IP Leaflet EN
    2011.12.01 1.67 MB Download
  • ecoLINE SIA IP firmware v5-07-2532 (USB)
    2017.12.01 1.82 MB Download
  • ecoLINE_SIA_BL
    2013.07.02 143.65 KB Download
  • Firmware upgrade instructions
    2014.03.10 519 bytes Download
  • Firmware upgrade instructions for versions earlier than v4.xx.xxxx
    2014.09.24 1.98 KB Download
  • Release notes (EN)
    2017.12.05 5.35 KB Download
no uploaded file

Product updates