Technical Support (on weekdays 8:00-17:00 Budapest time): +36 1 533 31 20

Technical Support: +36 1 533 31 20 (on weekdays 8:00-17:00 Budapest time) or [email protected]

Adapter2/Adapter2 PRO updates

On this page you can continuously check software and firmware updates, developments and bug fixes for Adapter2 and Adapter2 PRO products.

Latest updates:

Adapter2 és Adapter2 PRO Programozószoftver

Adapter2 Firmware

Adapter2 PRO Firmware

Adapter2 PRO WiFi Firmware

 

 

21.05.2024

New firmware and programming software version for Adapter2 has been released.

Firmware version: 8.2.0 (8323)

Remoter version: 8.1.1 (4859)

The firmware includes the following fixes:

  • Remote modem firmware updates (FOTA) could not be performed for Quectel EG91 modems
  • The @, {, _ characters in the SMS text were transmitted incorrectly
  • In versions equipped with the SIMCom A7682 modem, if the user removed the PIN-locked SIM card or the connection between the device and the SIM card was momentarily interrupted due to a contact error, the recorded PIN code was deleted. Therefore, after the error was resolved, the device could no longer restart.
  • Option for devices to connect to "SMS only" roaming network

 

The remoter includes the following fixes:

  • Remote firmware updates (FOTA) for the Quectel EG91 modem could not be performed, and it was not possible to exit the automatically popping up warning message
  • Correction of incorrect text that appeared during remote modem updates

 

 

19.03.2024

New firmware and programming software version for Adatper2, Adapter2 PRO and Adapter2 WiFi have been released. 

Firmware version: 1 V8.02.0 8311

Programming software version: V8.1.0.4856

 

The firmware includes the following bug fixes and developments:

  • Automatic APN determination in case of the SIMCOM A7682 modem
  • Preparation for FOTA capability for the SIMCOM A7682 modem
  • For transparent outgoing calls, if network congestion prevents a call from being initiated within 6 seconds, resulting in a failed attempt, this timeout period is extended to 20 seconds to accommodate for network delays.
  • SMS received from the service provider should not affect the device's startup process
  • Maintaining the sequence of calls according to the order set in the programming software

  

The programming software includes the following bug fixes and developments:

  • Introduction of FOTA updates for the SIMCOM A7682 modem
  • Transparent serial mode when connecting through the cloud
  • Error message received upon clicking the button to update the module registry list
  • Device firmware update through the cloud encounters an error

 

 

2023.09.13.

New firmware and programming software version for Adapter2 and Adapter2 PRO has been released.

 

Firmware version: v8.00.3.8245
Programming software version: v8.0.0.4818

 

The firmware contains the following bug fixes and developments:

 

  • When the device initiated a call while a live data connection was in progress for a SIMCOM A7682 modem, the call often failed
  • The programming software's status update for mobile technology types (GSM - UTRAN) was experiencing slow updates
  • If the phone number was not displayed during an incoming call, in the case of a SIMCOM A7682 modem, the previous phone number was identified by the device
  • After the shutdown of 3G, devices equipped with Quectel UG95/UG96 modems did not connect to 2G network
  • When the phone number exceeded the ’usual’ length (13 digits), the sent SMS was not received by the customer because part of the phone number was missed


The programming software contains the following bug fixes and developments:

 

  • Changing the SIA encryption key password field type so that it cannot be read again after input